three-dimensional electroanatomic mapping (eam) systems carto 3 version 6 Search Results


86
Biosense Webster carto 3 version 6 mapping system
Figure 3: Electroanatomic map integration. A: Map on the <t>CARTO</t> workstation (left) and corresponding view after import and registration to the cardiac CT in 3D Slicer (right). View from left lateral. B: Cardiac CT. Four chamber view (left column), two chamber view (center column), short axis view (right column). The map is shown as slice intersection on the CT. Yellow marker dots indicate good pace map locations. Upper row: Note the alignment of the map with the LV myocardium (brown). Middle row: The irradiation target is shown in green on the CT. Lower row: Final radiation dose map after addition of margins for motion and uncertainty. Colors indicate local dose from 5 Gy (blue) to 25 Gy (red).
Carto 3 Version 6 Mapping System, supplied by Biosense Webster, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/three-dimensional+electroanatomic+mapping+(eam)+systems+carto+3+version+6/electroanatomic+mapping+system/pm32648343-23-15-21
Average 86 stars, based on 1 article reviews
carto 3 version 6 mapping system - by Bioz Stars, 2026-09
86/100 stars
  Buy from Supplier

86
Biosense Webster pentaray mapping catheter
Figure 3: Electroanatomic map integration. A: Map on the <t>CARTO</t> workstation (left) and corresponding view after import and registration to the cardiac CT in 3D Slicer (right). View from left lateral. B: Cardiac CT. Four chamber view (left column), two chamber view (center column), short axis view (right column). The map is shown as slice intersection on the CT. Yellow marker dots indicate good pace map locations. Upper row: Note the alignment of the map with the LV myocardium (brown). Middle row: The irradiation target is shown in green on the CT. Lower row: Final radiation dose map after addition of margins for motion and uncertainty. Colors indicate local dose from 5 Gy (blue) to 25 Gy (red).
Pentaray Mapping Catheter, supplied by Biosense Webster, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/three-dimensional+electroanatomic+mapping+(eam)+systems+carto+3+version+6/catheter+mapping+multipolar+%E2%80%A2/pm32648343-23-29-40
Average 86 stars, based on 1 article reviews
pentaray mapping catheter - by Bioz Stars, 2026-09
86/100 stars
  Buy from Supplier

86
Biosense Webster thermocool smarttouch force sensing ablation catheter
Figure 3: Electroanatomic map integration. A: Map on the <t>CARTO</t> workstation (left) and corresponding view after import and registration to the cardiac CT in 3D Slicer (right). View from left lateral. B: Cardiac CT. Four chamber view (left column), two chamber view (center column), short axis view (right column). The map is shown as slice intersection on the CT. Yellow marker dots indicate good pace map locations. Upper row: Note the alignment of the map with the LV myocardium (brown). Middle row: The irradiation target is shown in green on the CT. Lower row: Final radiation dose map after addition of margins for motion and uncertainty. Colors indicate local dose from 5 Gy (blue) to 25 Gy (red).
Thermocool Smarttouch Force Sensing Ablation Catheter, supplied by Biosense Webster, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/three-dimensional+electroanatomic+mapping+(eam)+systems+carto+3+version+6/contact+force+sensing/pm32648343-23-34-40
Average 86 stars, based on 1 article reviews
thermocool smarttouch force sensing ablation catheter - by Bioz Stars, 2026-09
86/100 stars
  Buy from Supplier

Image Search Results


Figure 3: Electroanatomic map integration. A: Map on the CARTO workstation (left) and corresponding view after import and registration to the cardiac CT in 3D Slicer (right). View from left lateral. B: Cardiac CT. Four chamber view (left column), two chamber view (center column), short axis view (right column). The map is shown as slice intersection on the CT. Yellow marker dots indicate good pace map locations. Upper row: Note the alignment of the map with the LV myocardium (brown). Middle row: The irradiation target is shown in green on the CT. Lower row: Final radiation dose map after addition of margins for motion and uncertainty. Colors indicate local dose from 5 Gy (blue) to 25 Gy (red).

Journal: Journal of cardiovascular electrophysiology

Article Title: A novel open-source software-based high-precision workflow for target definition in cardiac radioablation.

doi: 10.1111/jce.14660

Figure Lengend Snippet: Figure 3: Electroanatomic map integration. A: Map on the CARTO workstation (left) and corresponding view after import and registration to the cardiac CT in 3D Slicer (right). View from left lateral. B: Cardiac CT. Four chamber view (left column), two chamber view (center column), short axis view (right column). The map is shown as slice intersection on the CT. Yellow marker dots indicate good pace map locations. Upper row: Note the alignment of the map with the LV myocardium (brown). Middle row: The irradiation target is shown in green on the CT. Lower row: Final radiation dose map after addition of margins for motion and uncertainty. Colors indicate local dose from 5 Gy (blue) to 25 Gy (red).

Article Snippet: Electroanatomic mapping A three-dimensional endocardial electroanatomic map of the left ventricle was acquired using the CARTO 3 version 6 mapping system (Biosense Webster, Diamond Bar, CA, USA) with the Pentaray mapping catheter and the Thermocool Smarttouch force sensing ablation catheter (Biosense Webster).

Techniques: Marker, Irradiation